A failing power circuit board will typically cause the unit to not power on at all. Meaning, you will not see the display lit up and the unit will not run and cool. The following guide will show you how to replace the power circuit board in your KC3000 series kegerator.
Models:
BR3000BL, BR3000SS, BR3001BL, BR3001SS, BR3002BL, BR3002SS
Tools Required:
- Phillips Screwdriver
- Flathead Screwdriver
- Needle Nose Pliers
NOTE: Disconnect the unit from the power source before attempting any repairs
Step 1: Remove the power circuit board cover
- On the back of the unit, remove the 4 Phillips screws securing the grated cover over the back of the unit
- Remove the cover to the circuit board by removing the two Phillips head screws and pressing in the two squeeze clips (one on each side)
Step 2: Remove and replace the power circuit board
NOTE: This would be a good time to take a picture of the electrical connections to help put them back in the right place later
- Using needle nose pliers or a flathead screwdriver, release the squeeze clips for the electrical connectors
- After all of the electrical connectors are removed, remove the Phillips screw holding the board in the housing
- Line the new circuit board up and install the two Phillips screws securing it to the housing
- Reinstall the electrical connectors
Step 3: Reinstall the circuit board cover
- Clip the circuit board cover to the housing
NOTE: There are cutouts for the wires to feed through. The wires must be properly fed through these cutouts to allow the cover to properly clip to the housing
- Once the cover is secured to the housing, install the two Phillips screws to attach the housing to the unit
- Reinstall the grated cover over the back of the unit
Procedure Complete!