Yes. Specific instructions for draining your EdgeStar dehumidifier can be found in the user manual that was packaged with your unit. Certain units can be drained continuously with a drain hose routed to a floor drain, other models include a built in pump to drain the unit. Each of these options is discussed below:
Continuous Drainage Models DEP301/501/701 and DEP400/650/700/740:
Note: This method relies on gravity to allow water to flow to a drain. There is no built in pump on this unit.
Please refer to the following instructional video and written steps:
- Remove the water bucket from the unit.
- Attach a 12 mm hose to the connector.
- Remove the rubber plug from the drain hose outlet, which is located on the back of the unit, and push the drain hose through.
- Securely attach the drain hose to the connector. Lead the other end of the hose to a floor drain or other suitable drainage port. Hose must allow water to flow downhill.
- You must reinstall the water bucket.
** Please note: This drain method requires that the water can freely flow to a suitable drain by way of gravity, i.e. downhill.
Continuous Drainage Models DEP500/700:
Note: This method relies on gravity to allow water to flow to a drain. Refer to the instruction at the end of this article for using the built in pump.
You may connect a hose to the continuous drain port located on the middle right of the backside of the unit. You will need to supply your own drain hose. You may use a standard garden hose with a ¾” connector fitting. The drain hose that is included with these models is intended for use with the built in pump option (see below).
- Locate the gravity drain hose port found on the back of the unit (located on the middle, right hand side)
- Unscrew the drain cover by turning counter clockwise and remove the rubber stopper.
- Screw the drain hose onto the threaded portion of the drain outlet and tighten firmly.
- Place the other end of the drain hose in a floor drain or other suitable drainage port.
** Please note: This drain method requires that the water can freely flow to a suitable drain by way of gravity, i.e. downhill.
Built In Pump Models DEP500/700:
- Locate the drain hose that was packaged with your dehumidifier.
- Insert the nozzle end of the drain hose into the drain pump port located on the lower back of the unit. The nozzle will click into place when attached properly.
- Route the other end of the drain hose to a suitable drain. The pump is capable of pumping water up to 16 ft. vertically or horizontally.